Course Content:

Our Qualitative Respirator Fit Testing adheres to the CSA Standard Z94.4-18, encompassing fit testing, as well as the selection, use, and maintenance of respirators (Z94.4-02). The program includes a minimum instructional component, the duration of which depends on the respirator type. Following this, a qualitative fit test is conducted using precise irritant smoke test methods.

The training covers essential topics such as regulatory requirements and wearer responsibilities in PPE usage, proper donning and doffing of respirators, care and maintenance procedures, including cleaning and sanitizing. Participants learn about the limitations of different respirators, inspection protocols, compatibility with other PPE, conducting seal/pressure checks, recognizing respiratory hazards, and guidance on selecting filters or cartridges based on the intended use of the respirator.

At Hightower Safety, we prioritize the use of the most accurate qualitative fit testing methods available.

Training and Fit Testing Guidelines:

Under the CSA Standards and in accordance with our OH&S Act and Regulations, qualitative respirator fit tests and PPE training must be undertaken every 2 years. Exceptions to this biennial schedule include instances where an individual changes jobs, experiences significant weight loss or gain, sustains a facial injury, changes or is requested to change respirators, or when workplace hazards are reassessed. In such cases, a fit test is mandatory. If uncertain, refer to the respirator's user manual for manufacturer-recommended guidelines, particularly if the two-year timeframe is not met.

In Preparation for your Fit Test:

  1. Candidates are required to be clean-shaven within 16 hours, adhering to CSA Standards, to undergo fit testing.

  2. Remove facial jewelry or any items that create a barrier between the skin and the respirator.

  3. Fit tests are conducted on specific makes and models of respirators, not on the entire category.

Fit Testing Pricing - Each Worker $95 + HST (Respirator Extra):

Includes:

  • Fit Test Wallet Card for Workers

  • Employer Qualitative Respirator Fit Test Record of Participants

  • How to Use/Clean Respirator

  • A Qualitative Irritant Smoke Test

Related Products:

6000 Series Half Facepiece Reusable Respirator, Thermoplastic (Small, Medium, Large)
CA$25.30
  • Respirator combines comfort and convenience with easy-to-adjust, soft head straps

  • Low profile respirator design does not interfere with wearing safety glasses

  • Can be diassembled, cleaned and reused

  • Replaceable cartridges and filters available

  • Includes: reclosable storage bag

  • Recommended industries include: construction, manufacturing, industrial maintenance, marine, mining, oil & gas transportation

  • Suggested applications: chemical clean-up and handling, chipping, chiseling and cleaning

North® 7700 Series Half-Mask Respirator (Small, Medium, Large)
CA$52.33
  • Non-allergenic silicone facepiece material conforms to facial features and doesn't harden with age

  • Easy to clean, extremely durable and resists distortion, ensuring a better fit

  • Contoured sealing flange and cradle suspension system eliminates discomfort caused by pressure points on facial nerves

  • Minimal dead air space improves worker comfort by limiting rebreathing of exhaled air

  • Direct cartridge to facepiece seal minimizes replacement parts and simplifies maintenance

  • Cartridges and filters sold separately

2000 Series Respirator Prefilters
CA$14.66

Brand: 3M

  • Light weight and easy to breathe through

  • Suited for a wide range of oil and non-oil based particulate contaminants

  • Used for (possible applications): Welding, metal pouring, pharmaceutical manufacturing

  • Priced per package

  • For use with:

    • 6500 Series Half Facepiece

  • Type: Particulate Filter

  • Qty/Pkg.: 2

  • Sold/Priced Per: Package

  • Model: SE909

  • Manufacturer Model No.: AB02091

North® Hard Shell Filters, Particulate Filter, P100 Filter
CA$18.34

Brand: 3M

  • Light weight and easy to breathe through

  • Suited for a wide range of oil and non-oil based particulate contaminants

  • Used for (possible applications): Welding, metal pouring, pharmaceutical manufacturing

  • Priced per package

  • For use with:

    • 770 Seris Half Mask Respirator

  • Type: Particulate Filter

  • Qty/Pkg.: 2

  • Sold/Priced Per: Package

  • Model: SM913

  • Manufacturer Model No.: 7580P100

Respirators & PPE Cleaning Wipes
CA$16.04

Brand: Zenith SafetyProcess

  • For rubber or latex face and mouth pieces, respirators, etc.

  • Alcohol-free

  • Avoids "drying-out" associated with alcohol based cleaners

  • Individually packaged

  • Format: Wipes

  • Length: 8"

  • Width: 5"

  • No. of Wipes: 100

  • Model: SEE383

To book or request more information, please contact us at info@hightowersafety.ca.

Our office can also be reached from Monday-Friday, 8 AM to 5 PM at 905-837-6773

Respirator Fit Test Training

Relevant Regulations:

  • CSA Standard Z94.4-18 (-11, -02, -18)

  • O. Reg. 213/91, sections 21, 26 and 93 under the Occupational Health and Safety Act

  • O. Reg. 490/09 (2019) under the Occupational Health and Safety Act - Medical Surveillance for Designated Substances *New for January 2020

  • O. Reg. 449/19 Occupational Exposure Limits (OEL)

  • OHS Act and Regulations that pertain to the use of respirators, multiple sections of the green book. Anyone required to wear a respirator on the job is required to be trained in it's use and have a fit test at least every two years.